Application:

The 8kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant

Also known as:

4/0 AWG HVTECK 8kV Aluminum Cable 1/C 8kV TRXLPE AIA Cable 4/0 AWG HVTECK 133% Insulation Cable Aluminum Armored Power Cable (8kV) CSA 4/0 AWG HVTECK Medium Voltage Cable Orange Jacket 8kV CSA Cable 8kV CSA Armored Aluminum Cable

Construction:

Conductor:
Class B compact stranded 8000 Series aluminum per ASTM B800 and ASTM B836
Conductor Shield:
Semi-conducting cross-linked copolymer; A conductor separator is used for cable size larger than or equal to 500 Kcmil

Insulation:
140 Mils Tree Retardant Cross Linked Polyethylene 133% insulation level
Insulation Shield: 
Strippable semi-conducting cross-linked copolymer
Copper Tape Shield:
Helically wrapped 5 mil copper tape with 25% overlap
Inner Jacket:
PVC inner jacket

Armour:
Aluminum Interlocked Armour (AIA)

Overall Jacket:
Orange Polyvinyl Chloride (PVC) Jacket

Standards:

• ASTM B801 Concentric-Lay-Stranded Conductors of 8000 Series Aluminum Alloy
• ASTM B836 Compact Rounded Stranded Aluminum Conductors
• CSA C22.2 No. 174 Cables in Hazardous Locations
• CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications – 5 to 46 KV
• CSA C68.3 Shielded & Concentric Neutral Power Cable – 5 to 46 kV
• CSA LTGG [-40°C] – as per C68.10 – for Cold Bend and Impact rating
• CSA HL – for Hazardous Locations rating
• CSA SUN RES – for Sunlight Resistant rating
• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
• ICEA T-29-520 Flame Test (210,000 BTU/Hr)
• IEEE 383 Flame Test (70,000 btu)
• IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test (1/0 and Larger)

Specification:

• Size: 4/0 AWG
• Number of Strands: 19
Diameter Over Conductor (inch):   0.474
Diameter Over Insulation (inch): 0.792
• Insul Thickness:  140
Diameter Over Insulation Shield:  0.852
• Jacket Thickness (mil):  80
Dia. Over Armour:   1.364
Overall Jacket Thickness:    50
• Approx. OD (In):  1.464
Approx. Weight (Lbs/1000’Ft): 881
DC Resistance @ 25°C Ω /1000ft:   0.084
AC Resistance @ 90°Ω /1000ft:    0.105
Allowable Ampacity In Air 90°C: 329
Allowable Ampacity Directly Buried 90°C: 309