500 kcmil 3-Core MV-105 Copper Power Cable – 15kV Rated, NLEPR Insulated, 133% IL, 50% Ground, AIA-Compliant, Red PVC Sheath

$19.90

In stock

Quantity

Description

[short] [pdf] [/pdf]

500 MCM 3C Type MV-105 Copper 15kV NLEPR 133% IL 50% Ground AIA Red PVC Jacket

Application:

The 15KV cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated at -35°C for cold bend when UL listed. Rated at -40°C for cold bend and cold impact and marked with “LTGG” when CSA listed or dual UL/CSA listed. For uses in Class I and II, Division 2 hazardous locations per NEC Article 501 and 502.Rated for 1000 lbs./ FT maximum sidewall pressure. The ground is sized to equal 50% of the phase conductor. Silicone free cable Type MV-105 Three Conductor Copper, 220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level, Tape Shield, 50% Ground Aluminum Interlocked Armor (AIA), Polyvinyl Chloride (PVC) Jacket. Silicone Free. Silicone Free>

Also known as:

500 MCM 3C MV-105 15kV Copper Cable with NLEPR Insulation, 50% Ground and PVC Jacket Three Conductor 15kV Copper 500 MCM 3C  Power Cable with NLEPR and 50% Grounding 15kV Copper Cable with 133% IL NLEPR Insulation and Red PVC Jacket Red PVC Jacketed 15kV Copper 500 MCM 3C Cable with AIA Insulation and 50% Ground 15kV Copper Power Cable with 50% Ground, NLEPR Insulation, and PVC Jacket 500 MCM 3C MV-105 Copper Cable 15kV with 50% Ground and AIA Red PVC Jacket Three Conductor Copper 15kV Cable with NLEPR Insulation, 50% Grounding, and PVC Jacket 15kV Copper Cable 500 MCM 3C with NLEPR Insulation, 50% Ground, and Red PVC Outer Jacket

Construction:

Conductor:
Class B compressed stranded bare copper per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)
Conductor Shield:
Semi-conducting cross-linked copolymer

Insulation:
220 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% Insulation Level,
Insulation Shield: 
Strippable semi-conducting cross-linked copolymer
Copper Tape Shield:
Helically wrapped 5 mil copper tape with 25% overlap
Grounding Conductor:
Three separate ground wires with a combined circular mil of 50% of the phase conductor. Class B compressed stranded bare copper per ASTM B3 and ASTM B8 (Tinned Copper per ASTM B33 optional)

Filler:
Non-hydroscopic wax paper filler

Binder:
Polypropylene tape

Armor:
Aluminum Interlocked Armor (AIA)

Overall Jacket:
Polyvinyl Chloride (PVC) 

Standards:

• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• ASTM B33 Standard Specification for Tin-Coated Soft or Annealed Copper Wire
• UL 1072 Medium-Voltage Power Cables
• UL 1685 Vertical-Tray Fire Propagation and Smoke Release Test
• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable

Specifications:

Size: 500 MCM
Number of Conductor: 3 + 3G
Number of Strands:  37
Diameter Over Conductor (inch): 0.789
• Diameter Over Insulation (inch):   1.252
Diameter Over Insulation Shield (inch):  1.312
Ground No. x AWG:  3×1
Diameter Over Armor (inch):   3.205
Jacket Thickness (mil):   90
Approx. OD (In): 3.393
Copper Weight lb/1000ft: 5776
Approx. Weight (Lbs/1000’Ft): 8611
DC Resistance @ 25°C Ω /1000ft:   0.022
AC Resistance @ 90°Ω /1000ft: 0.030
Allowable Ampacity In Duct 90/105°C Amp :   450/485
Allowable Ampacity In Air 90/105°C Amp:  535/600

Explore more from our collection.

Reviews

There are no reviews yet.

Be the first to review “500 kcmil 3-Core MV-105 Copper Power Cable – 15kV Rated, NLEPR Insulated, 133% IL, 50% Ground, AIA-Compliant, Red PVC Sheath”

Your email address will not be published. Required fields are marked *