3/0 AWG HVTECK Copper 3-Conductor 35kV High-Voltage Cable – NLEPR Insulation, 420 Mil, 133% IL, Black PVC Jacket, CSA Certified

$19.90

In stock

Quantity
SKU: NNC648784 Category: Brand:

Description

[pdf]  [/pdf]

3/0 AWG 3C HVTECK Copper 420 mil NLEPR TS AIA 35kV 133% IL Black PVC Jacket CSA

Application:

The 35kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant.

Also Known As:

3/0 AWG 3C 3/C 420 mil Copper Cable, HVTECK 35kV Copper Wire, NLEPR 3 Conductor Cable, 35kV 3/C Copper Cable, Copper 420 mil 3C Cable, 3/0 AWG 3C AIA 35kV Copper Cable, PVC Jacketed Copper Cable, 3/C 35kV Copper Wire, 3 Conductor 420 mil Cable, 3/0 AWG 3C CSA Certified Copper Cable.

Construction:

• Conductor: Class B compressed stranded bare copper per ASTM B3 and ASTM B8
• Conductor Shield: 
Semi-conducting cross-linked copolymer
• Insulation: 
420 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 133% insulation level
• Insulation Shield: 
Strippable semi-conducting cross-linked copolymer
• Copper Tape Shield:
 Helically wrapped 5 mil copper tape with 25% overlap
• Filler: 
Interstices filled with non-hydroscoping/non-wicking fillers
• Grounding Conductor: 
Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8
• Binder: 
Polypropylene tape
• Inner Jacket:
 PVC inner jacket
• Armour: 
Aluminum Interlocked Armour (AIA)
• Overall Jacket: 
Black Polyvinyl Chloride (PVC) Jacket

Standards:

• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• CSA C22.2 No. 174 Cables in Hazardous Locations
• CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications – 5 to 46 KV
• CSA C68.3 Shielded & Concentric Neutral Power Cable – 5 to 46 kV
• CSA LTGG [-40°C] – as per C68.10 – for Cold Bend and Impact rating
• CSA HL – for Hazardous Locations rating
• CSA SUN RES – for Sunlight Resistant rating
• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
• ICEA T-29-520 Flame Test (210,000 BTU/Hr)
• IEEE 383 Flame Test (70,000 btu)
• IEEE 1202 FT4 Flame Test (70,000) BTU/hr Vertical Tray Test
• FT1 Flame Test (1,706 BTU/Hr nominal – Vertical Wire Flame Test)
• AEIC CS-8 Specification for extruded dielectric shielded power cables rated for 5 through 46KV (Qualification Test Requirements)

Specifications:

• Size: 3/0 AWG
• Number of conductor: 3
• Number of Strands: 19
• Diameter Over Conductor (inch):   0.456
• Diameter Over Insulation (inch):   1.334 
• Insul. Thickness mil: 420
• Diameter Over Insulation Shield (inch): 1.394
• Ground Size AWG: 6
• Inner Jacket Thickness (mil):  125
• Diameter Over Armor (inch):  3.660
• Overall Jacket Thickness mil :  85
• Approx. OD inch :  3.830
• Copper Weight lb/1000ft:  1781
• Approx. Weight (Lbs/1000’Ft):  6620
• Min Bending Radius (In):   26.8
• DC Resistance @ 25°C Ω /1000ft:  0.064
• AC Resistance @ 90°Ω /1000ft:   0.081
• Inductive Reactance @ 60HzΩ/1000ft:  0.048
• Allowable Ampacity In Air 90°C Amp:  303
• Allowable Ampacity Directly Buried 90°C Amp:  327