Description
[short] [pdf] [/pdf]
2/0 AWG 3C HVTECK Copper 90 mil NLEPR TS AIA 5kV 100% IL Orange PVC Jacket CSA
Application:
The 5kV HVTECK is a CSA armoured cable for industrial and commercial medium voltage applications. Rated FT4, -40°C, Hazardous Locations (HL). These cables are capable of operating continuously at the conductor temperature not in excess of 105°C for normal operation, 140°C for emergency overload, and 250°C for short circuit conditions. Rated for 1000 lbs /FT maximum sidewall pressure. These cables feature sunlight and moisture resistance, exceptional corona resistance, resistance to most chemical soils and acids and are flame retardant 3 Conductor, 90 Mils No Lead Ethylene Propylene Rubber (NL-EPR), 100% Insulation Level, Tape Shield, Polyvinyl Chloride (PVC) Inner Jacket, Aluminum Interlocked Armour (AIA), Polyvinyl Chloride (PVC) Jacket
Also known as:
2/0 AWG 3C HVTECK Copper 3 Conductor 90 mil TRXLPE Armored Cable 5kV CSA Certified Copper Power Cable with PVC Jacket 5kV Copper Armored Power Cable with PVC Jacket 2/0 AWG 3C HVTECK 5kV CSA Copper 3 Conductor PVC Cable 3-Copper Conductor 5kV Cable with Interlocked Armor 5kV High Voltage Copper Shielded Cable 90 mil Copper 5kV PVC Insulated Cable with AIA Armor 2/0 AWG 3C HVTECK 5kV PVC Jacketed Copper Cable for Direct Burial
Construction:
Conductor:
Class B compressed stranded bare copper per ASTM B3 and ASTM B8
Conductor Shield:
Semi-conducting cross-linked copolymer
Insulation:
90 Mils No Lead Ethylene Propylene Rubber (NL-EPR) 100% insulation level
Insulation Shield:
Strippable semi-conducting cross-linked copolymer
Copper Tape Shield:
Helically wrapped 5 mil copper tape with 25% overlap
Filler:
Interstices filled with non-hydroscoping/non-wicking fillers
Grounding Conductor:
Class B compressed stranded bare copper ground per ASTM B3 and ASTM B8
Binder:
Polypropylene tape
Inner Jacket:
PVC inner jacket
Armour:
Aluminum Interlocked Armour (AIA)
Overall Jacket:
Orange Polyvinyl Chloride (PVC) Jacket
Standards:
• ASTM B3 Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• CSA C22.2 No. 174 Cables in Hazardous Locations
• CSA C22.2 No. 2556 & No. 0.3 Wire and Cable Test Methods
• CSA C68.10 Shielded Power Cables for Commercial and Industrial Applications – 5 to 46 KV
• CSA C68.3 Shielded & Concentric Neutral Power Cable – 5 to 46 kV
• CSA LTGG [-40°C] – as per C68.10 – for Cold Bend and Impact rating
• CSA HL – for Hazardous Locations rating
• CSA SUN RES – for Sunlight Resistant rating
• ICEA S-93-639 (NEMA WC 74) 5-46 KV Shielded Power Cable
• ICEA T-29-520 Flame Test (210,000 BTU/Hr)
Specification:
•Size: 2/0 AWG
•Number of conductor: 3
• Number of Strands: 19
• Diameter Over Conductor (inch): 0.405
• Diameter Over Insulation (inch): 0.624
• Insul. Thickness mil: 90
• Diameter Over Insulation Shield (inch): 0.684
• Ground Size AWG: 6
• Inner Jacket Thickness (mil): 110
• Diameter Over Armor (inch): 2.091
• Overall Jacket Thickness mil : 60
• Approx. OD inch : 2.211
• Copper Weight lb/1000ft: 1544
• Approx. Weight (Lbs/1000’Ft): 3050
• DC Resistance @ 25°C Ω /1000ft: 0.081
• AC Resistance @ 90°Ω /1000ft: 0.102
• Allowable Ampacity In Air 90°C Amp: 260
• Allowable Ampacity Directly Buried 90°C Amp: 292
|
Compatible with Manufacturer |
|
| Southwire | 576703 |