14 AWG 9-Conductor Flame-Retardant XLPE Control Cable with CPE Jacket – 600V

$19.90

In stock

Quantity
SKU: NNC659872 Category: Brand:

Description

[pdf]  [/pdf]

14 AWG 9C Copper FR-XLPE CPE Jacket Control Cable 600V

Applications:

The 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10

Also Known As:

14 AWG 9C 600V Control Cable, 14 AWG 9C FR-XLPE Insulated Control Cable, 16/2 CPE Jacketed Control Cable Flame-Retardant XLPE Control Cable, Industrial Control Cable XLPE/PVC Control Cable, Type TC-ER Cable, UL 1277 Cable, 600 Volt Instrumentation Cable.

Construction:

Conductor:
7 strands class B compressed bare copper per ASTM B3 and ASTM B8

Insulation:
Flame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes

Filler:
Polypropylene filler on cables with 5 or less conductors

Binder:
Polyester flat thread binder tape applied for cables with more than 5 conductor
Rip Chord:
Rip chord for ease of jacket removal

Overall Jacket:
Chlorinated Polyethylene (CPE) Jacket

Standards:

• ASTM B3 Standard Specification for Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• UL 1277 Electrical Power and Control Tray Cables
• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 – (210,000 Btu/hr)
• VW-1 (Vertical-Wire) Flame Test

Specification:

• Size: 14 AWG 
• Number of Conductors: 9
• Diameter Over Conductor (inch): 0.070
• Insulation Thickness (Mil):  30
• Jacket Thickness (Mil): 60
• Approx. OD (In): 0.588
• Copper Weight (Lbs/1000’Ft):  115
• Approx. Weight (Lbs/1000’Ft):  236
• DC Resistance Ω /1000ft: 2.630 
• AC Resistance @ 90°C Ω /1000ft:  3.288
• Min Bending Radius (In):  2.4
Allowable Ampacity At 60°C:   12
• Allowable Ampacity 75°C:  15
• Allowable Ampacity 90°C:  15