10 AWG 2-Conductor Copper Control Cable – FR-XLPE Insulated, CPE Jacketed, 600V

$19.90

In stock

Quantity
SKU: NNC102TBA Category: Brand:

Description

[pdf]  [/pdf]

10 AWG 2C Copper FR-XLPE Thermoset CPE Jacket Control Cable 600V

Applications:

Southwire’s 600 Volt control cables are suited for use in wet and dry areas, conduits, ducts, troughs, trays, direct burial, aerial supported by a messenger, and where superior electrical properties are desired. These cables are capable of operating continuously at the conductor temperature not in excess of 90°C for normal operation in wet and dry locations, 130°C for emergency overload, and 250°C for short circuit conditions. UL rated constructions can be used in Class I, II, and III, Division 2 hazardous locations per NEC Article 501 and 502. UL rated constructions with 3 or more conductors are listed for exposed runs (TC-ER) per NEC 336.10.

Also Known As:

10 AWG 2C Multi-Conductor Copper Control Cable, 10 AWG 2C 600V, FR-XLPE Insulation, CPE Jacket,10 AWG 2C Flame-Retardant XLPE CPE Jacketed Control Cable, 10 AWG 2C 600V,Thermoset Insulated Multi-Conductor Control Cable,10 AWG 2C 600V FR-XLPE/CPE Industrial Control Cable,10 AWG 2C Multi-Conductor XLPE Insulated CPE Jacket Cable, Copper Control Cable with FR-XLPE and CPE Jacket, 10 AWG 2C 600 Volt, 600V Thermoset XLPE/CPE Jacketed Copper Cable,10 AWG 2C Multi-Conductor 600V XLPE/CPE Copper Control Wire

Standards:

 ASTM B3 Standard Specification for Soft or Annealed Copper Wire
• ASTM B8 Concentric-Lay-Stranded Copper Conductors
• UL 1277 Electrical Power and Control Tray Cables
• UL 1685 FT4 Vertical-Tray Fire Propagation and Smoke Release Test
• ICEA S-58-679 Control Cable Conductor Identification Method 1 Table 2
• ICEA S-73-532 Standard for Control, Thermocouple Extension and Instrumentation Cables
• ICEA S-95-658 (NEMA WC70) Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy
• IEEE 1202 FT4 Vertical Tray Flame Test (70,000 Btu/hr) and ICEA T-29-520 – (210,000 Btu/hr)
• VW-1 (Vertical-Wire) Flame Test

Construction:

Conductor:
7 strands class B compressed bare copper per ASTM B3 and ASTM B8
Insulation:
Flame Flame Retardant Cross Linked Polyethylene (FR-XLPE), 30 Mils thick for all cable sizes
Filler:
Polyester flat thread binder tape applied for cables with more than 5 conductors

Binder:
Polyester flat thread binder tape applied for cables with more than 5 conductors

Rip Chord:
Rip chord for ease of jacket removal

Overall Jacket:
Thermoset Chlorinated Polyethylene (CPE) Jacket

Specifications:

• Size: 10 AWG 
• Number of Conductors: 2
• Diameter Over Conductor (inch):  0.111
• Insulation Thickness (Mil): 30
• Jacket Thickness (Mil): 45
• Approx. OD (In):  0.431
• Copper Weight (Lbs/1000’Ft):   65
• Approx. Weight (Lbs/1000’Ft):   124
• Min Bending Radius (In):1.7
• Allowable Ampacity In Air 90°C (Amp):   30